Portable Gas Detectors
Portable Gas Detectors Perth
CONTACT FOR ENQUIRIESDräger X-zone* 5800:
- Dimensions (W x H × D): 490 x 300 x 300 mm / 20 × 12 x 12 in.
- Weight: 10 kg (22 Ibs.) (24 Ah battery)
- Ambient conditions: Temperature: -20 °C – max. +50 C / -4 °F – max. + 122 °F / Pressure: 700 to 1,300 hPa / Humidity: 10 to 95 % r.h.
- Ingress Protection: IP67
- Alarm: Visual 360° LED (illuminated ring) / Audible 360°; >108 dB in a distance of 1 m (3 ft.), 120 dB in a distance of 30 cm (1 ft.) / Configurable alarm patterns, frequencies and volumes
- Life signal: Green status display (360°), illuminated ring (LED)
- Operating time: Approx. 120 h (24 Ah battery), Depending on sensor equipment / configuration of the life signal
- Charging time: Approx. 14 h
- Flexible power supply: Exteral 100 – 240 V charger (worldwide) or inductive wireless charger
- Pump operation: Maximum hose length: 45 m (150 ft.), 30 m (100 ft.) for zone 0
- Alarm output: Potential-free alarm contact for intrinsically safe circuits (6-pole); < 20 V to 0.25 A (0.15 A constant current); Resisting load
- Radio transmission: Worldwide license-free ISM frequencies / Digital radio, robust and interference-free transmission up to 100 m (328 ft.)
- RF approvals: 868 MHz (EU, Norway, Switzerland), 915 MHz (USA, Canada, Singapore, Australia), 433 MHz (Russia, Malaysia)
- Approvals: ATEX: I M1 Ex ia I Ma, Il 1G Ex ia IIC T4 Ga / IECEX: Ex ia I Ma, Ex ia IIC T4 Ga
Power Supply Ex:
- Dimensions: 365 x 320 x 250 mm
- Weight: 10 kg
- Protection class: IP 44
- Approvals: ATEX: Il (1)G (Ex ia Ga) IIC / IEC Ex: [Ex ia Ga] IIC / CSA/US: Pending
- Temperature range: -20 °C to +50 °C
- Cable length: Cable drum 50 m, Connection cable fix 0.5 m + Power Cord EU, UK, US or AUS 3 m