Your Equipment Hire People
Contact Graeme: 0499 144 077 / graeme@exee.com.au
Contact Travis: 0405 439 787 / travis@exee.com.au

Exee Certified Inspections

ATEX Inspections (ATmosphere EXplosible)

EX Electrical provide ATEX Inspections to all organisations, in the following industries:

  • Oil & Gas
  • Mining & Industry
  • Chemical
  • Steel
  • Engineering

The certified inspections we provide to you will ensure your organisation is fully compliant. We ensure all installed ATEX electrical and mechanical equipment is certified. This includes having right protection concept for the potentially explosive atmosphere, ensuring it is safe to use and fit for purpose.

We offer the following services:

  • ATEX Inspections – Electrical and Instrumentation
  • ATEX Inspections – Mechanical
  • ATEX Inspections – Strategy Development and Implementation
  • Verification and Compliance
  • ATEX Installation
  • Ex Register Development and Updates
  • PDA and Seoftware Options
  • Modifications and Repair Services
  • Gap Analysis
  • ATEX Inspections – Trade Awareness Training
  • Explosion Certified Documentation
  • Equipment Manuals

ATEX Inspections Documentation

  • Certified ATEX Inspections Report (Visual, Close or Detailed Inspections)
  • Certified ATEX Installation Certificate (For Installations by EXEE)
  • Ex Register
  • Summary Report – Recommendations, Corrective Actions and Advisory Notes
  • Signed Inspection Check-Sheets in line with AS/NZS 60079-17: 2014
  • Explosion Protection Cerificates/Documents
  • Equipement Manual

Youtube video thumbnail off shore oil rig

Certified Inspections

DSEAR Inspections (Dangerous Substance and Explosive Atmosphere Regulation)

DSEAR Inspections

The DSEAR is a UK legal regulation. The European ATEX directives are integrated into to the DSEAR regulations and place the same responsibilities on employers to ensure that work places storing or handling dangerous or flammable substances are made safe for employees to carry out their work.

EXEE Electrical provide DSEAR inspections that:

  • Supply documented evidence verifying all installed electrical or mechanical equipment is certified
  • Ensure all installed electrical or mechanical equipment has:
    • the correct protection concept
    • is fit for purpose
    • is safe to use in the potentially explosive atmosphere area.

DSEAR Inspection Services and Documentation

  • DSEAR Inspections – Electrical and Instrumentation
  • DSEAR Inspections – Mechanical
  • DSEAR Inspections – Strategy Development and Implementation
  • Verification and Compliance
  • DSEAR Electrical Equipment Installation
  • Ex Register Development and Updates
  • PDA and Software Options
  • Modifications and Repair Services
  • Gap Analysis
  • DSEAR Inspections – Trade Awareness Training
  • Explosion Certified Documentation
  • Equipment Manuals

Certified Inspections

HAZARDOUS AREA EX INSPECTIONS

Hazardous Area Inspection Types

There are 2 types of Hazardous Area Inspections:

1. Initial Inspections

To ensure the correct type of protection is appropriate for the hazardous area installation, an initial inspection is required.

2. Periodic Inspections

Periodic inspections need to be carried out as part of the overall maintenance and will apply to existing installations. The periodic inspection will identify any change and/or deterioration and should not exceed 3 years.

Hazardouss AreaAEx Inspections

Grades of Hazardous Area Inspections:

There are three grades of Hazardous Area Inspections:

1. Visual Hazardous Area Inspections

Visual hazardous area inspections identify without using tools and access equipment. They rely on the eye to identify and issues such as missing bolts and so on.

2. Close Hazardous Area Inspections

Close hazardous area inspections encompasses those aspects covered by a visual inspection, and in addition, identifies those defects (such as loose bolts), which will become apparent only when access equipment is used. Close inspections do not normally require the enclosure to be opened, or the equipment to be isolated.

3. Detailed Hazardous Area Inspections

A detailed hazardous area inspection will encompass those aspects covered by a close inspection and, in addition, identify those defects, such as loose terminations, which only become obvious when an enclosure is opened or using where necessary, tools and test equipment.

Youtube video thumbnail off shore oil rig

Hazardous Area Installation & Maintenance Project Management

EX Electrical provide assistance with carrying out necessary hazardous area installation and corrective maintenance using our teams of project engineers, electricians and technicians. We tailor all our site services to meet the specific needs of your maintenance and project work requirements. By providing DSEAR & ATEX hazardous area site compliance and hazardous area installation services, we can cover inspection & testing, installation and maintenance in hazardous areas consisting of:

  • Combustible Dusts
  • Explosive Gases and Vapours
  • Intrinsically Safe Systems

EX Electricals highly trained, skilled and experienced CompEx certified engineers, technicians and electricians have specialised expertise in hazardous area electrical installation, inspection and testing, as well as the maintenance of installations employing types of protection ‘d’, ‘e’, ’n’ and ’i’ as defined by AS/NZS 60079 17.14.

Our E&I Services include:

  • Hazardous Area (ATEX/DSEAR) Equipment Inspections
  • Electrical Installation & Maintenance Electrical Services
  • Instrumentation & Control
  • Process Instrument Calibration
  • E&I Skid Installations, Commissioning and Maintenance
  • Personnel Hire and Technical Procurement
  • Commissioning & Maintenance
  • Control Panel Design and Build
  • Test Instrument Calibration
  • Electrical Inspection & Testing

IEC Inspections

EX Electrical conduct ATEX, DSEAR or IEC inspections that follow the AS/NZS 60079-17 Standards. The industry standard for hazardous area inspections is the Electro Technical Commission Standard. This is used worldwide by organisations across a wide range of industries including:

  • Oil & Gas
  • Mining & Industry
  • Chemical
  • Steel
  • Engineering

Our inspectors utilise the IEC 600079-17 (The Inspection and Maintenance of Electrical Installations in Hazardous Areas) Standard for all inspections. EX Electrical specialise in providing IEC inspections, installation, maintenance and consultancy services.

IEC Inspections and Consultancy Services

  • IEC Inspections – Electrical and Instrumentation
  • IEC Inspections – Mechanical
  • IEC Inspections – Strategy Development and Implementation
  • Verification and Compliance
  • Installation
  • Ex Register Development and Updates
  • PDA and Seoftware Options
  • Modifications and Repair Services
  • Gap Analysis
  • IEC Inspections – Trade Awareness Training
  • Explosion Certified Documentation
  • Equipment Manuals

Youtube video thumbnail off shore oil rig

The IEC inspections we do will assist your organisation become compliant and will demonstrate that all installed electrical and mechanical equipment:

  • is certified
  • has the right protection concept for the potentially explosive atmosphere
  • is safe to use and fit for purpose.

IEC Inspection Documentation

  • Certified IEC Inspections Report (Visual, Close or Detailed Inspections)
  • Certified IEC Installation Certificate (For Installations by C&P Engineering Services)
  • Ex Register
  • Summary Report – Recommendations, Corrective Actions and Advisory Notes
  • Signed Inspection Check-Sheets in line with AS/NZS 60079-17: 2014
  • Explosion Protection Cerificates/Documents
  • Equipement Manuals

AS/NZS 60079 Associated Standards

Please see the following relevant associated standards:

  • AS/NZS 60079-0 Part 0: Equipment General Requirements
  • AS/NZS 60079-1 Part 1: Equipment protection by flameproof enclosures “d”
  • AS/NZS 60079-2 Part 2: Equipment protection by pressurized enclosures “p”
  • AS/NZS 60079-7 Part 7: Equipment protection by increased safety “e”
  • AS/NZS 60079-10 Part 10: Classification of hazardous areas
  • AS/NZS 60079-11 Part 11: Equipment protection by intrinsic safety “i”
  • AS/NZS 60079-14 Part 14: Electrical Installations in Hazardous Areas (other than mines)
  • AS/NZS 60079-15 Part 15: Construction, test and making of type of protection “n” electrical apparatus

Certified Inspections

Offshore Services & Inspections

Youtube video thumbnail off shore oil rig

EXEE provides Offshore Ex Inspections and assists in compliance requirements in the following areas:

  • contract specifications
  • asset integrity
  • safety
  • international codes
  • regulatory compliance

This is met by providing scheduled and un-scheduled inspection services, all serviced by our highly qualified engineers, electricians and technicians. As a minimum our personnel are certified to CompEx 01 – 04, posses AME Medical Certificates, are BOSIET / HUET Certified and hold MIST certification.

Offshore EX Inspections

  • Electrical surveys (visual, close and detailed inspection of EX Equipment)
  • Ex Hazardous Area Inspection Strategy Development & Implementation
  • Compiling Ex Registers and Client Databases
  • Ensuring Verification of all Installed ‘Ex’ Equipment Databases
  • Ensuring Compliance with all Standards and Regulations
  • Gap Analysis and Reporting of Current Ex Inspection Procedures
  • Explosion Protection Documents
  • Ex Installation & Maintenance Project Management
  • Ex Remedial Repairs
  • Solutions for PDA, Software Data Capture and Management (including RFID)

Full E&I Installation

  • Maintenance & Support Services
  • E&I Personnel Supply
  • Process Instrument Calibration
  • Commissioning and decommissioning of all electrical appliances
  • Instruments (installation and maintenance
  • New electrical installations and upgrades together with support systems
  • ATEX inspection
  • Electrical maintenance programmes
  • EX audits and/or EX registers to conform with international compliance

What Our CLients Say

Certified Inspections

AusEx / CompEx / IECEx Certified Inspections.

2 people testing hazardous area equipment

HVACR Solutions

Quality, reliable, fit for purpose and cost effective solutions.

HVACR

Health & Safety

Ensuring a lost time injury free work place.

Health and safety inspection being done

Rental Equipment

Tons of equipment and tools for rental at affordable cost.

Example of equipment for rent

We are Approved Vendor for:

Quadrant Energy Baker Hughes Sonomatic Aussie Fluid Power Weatherford Airpac Bukom Amphenol FMC Dart Energy TMT Schlumberger MI SWACO